Particle Attrition Characteristics in a Bubbling Fluidized Bed Under High Temperature and High Pressure Conditions 


Vol. 20,  No. 4, pp. 359-366, Dec.  2014


PDF
  Abstract

Attrition characteristics of PKM1-SU particles, CO2 absorbents for pre-combustion CO2 capture process, and FCC particles, catalytic particles for hydro cracking of crude oil, were investigated at high temperature and high pressure conditions. Particle attrition tests were executed at various kinds of temperature (0-400 ℃) and pressure (0-20 bar) conditions in a cylinder type bubbling fluidized bed with 15.1 cm diameter, 120 cm height and 1 mm orifice-sparger tube. Attrited particles before and after tests were analyzed by BET, optical microscopy, and particle size analyzer. Effects of bed material height (solid inventory) and steam injection were also verified by using ASTM D5757-95, conventional attrition test method.

  Statistics
Cumulative Counts from November, 2022
Multiple requests among the same browser session are counted as one view. If you mouse over a chart, the values of data points will be shown.


  Cite this article

[IEEE Style]

M. JH, L. DH, R. HJ, P. YC, L. JS, M. BM, J. GT, "Particle Attrition Characteristics in a Bubbling Fluidized Bed Under High Temperature and High Pressure Conditions," Clean Technology, vol. 20, no. 4, pp. 359-366, 2014. DOI: .

[ACM Style]

Moon JH, Lee DH, Ryu HJ, Park YC, Lee JS, Min BM, and Jin GT. 2014. Particle Attrition Characteristics in a Bubbling Fluidized Bed Under High Temperature and High Pressure Conditions. Clean Technology, 20, 4, (2014), 359-366. DOI: .