Investigation on Desorption Reaction and Heating Value of Used Activated Carbons Collected from VOC Adsorption Towers 


Vol. 16,  No. 1, pp. 33-38, Mar.  2010


PDF
  Abstract

The characteristics of desorption reaction and the heating values of used activated carbons collected from the companies of Shiwha/Banwal industrial complex were investigated. The desorption characteristics of used activated carbons were analyzed based on the data obtained from a thermogravimetric analyzer. The activation energies and reaction orders for desorption reaction of used activated carbons were calculated by employing Freeman-Carroll method. Heating values of volatile organic compounds(VOC) desorbed from used activated carbons were estimated based on the data obtained from a total hydrocarbon analyzer. It was found that the reaction orders of desorption of used activated carbons were 0.1~0.8, their desorption activation energies, 6.9~26.4 kJ/mol, and VOC heating values, 0.4~10.7 kcal/kg.

  Statistics
Cumulative Counts from November, 2022
Multiple requests among the same browser session are counted as one view. If you mouse over a chart, the values of data points will be shown.


  Cite this article

[IEEE Style]

Y. SM, K. JY, P. K, Y. SK, K. IS, P. HJ, R. YW, "Investigation on Desorption Reaction and Heating Value of Used Activated Carbons Collected from VOC Adsorption Towers," Clean Technology, vol. 16, no. 1, pp. 33-38, 2010. DOI: .